Brands · Plates + boxes + banks · Sep 2026 street lists
Inverex
Local name for hybrid boxes, Mustang plates, LFP and tubular. Service is the product. Mustang TOPCon 585–620 W is the plate line. Nitrox is the house hybrid.
Origin
Pakistan brand / import
Service in PK
Widest city service
Pick / skip
Pick: When you need a board replaced in your city.
Skip: Assuming Mustang = Hi-MO X10. Different cell, different paper.
How we use it
Nitrox silk-screen: PV+/PV−, BAT+/BAT−, GRID, LOAD (backup), optional GEN. Power-on: pack ON and CAN first, LCD battery type (LIB/PYL/brand — not USE), then PV isolator, then GRID, then LOAD. Shed-test the fridge before the installer leaves. 24 V Yukon/Veyron 4 kW must not see a 51.2 V DL5.0C.
App: SmartESS or Solarman, owner account. Mustang plates are local-branded import — same torque as any 600 W module, not Hi-MO X10 paper. Inverex LFP pairs on CAN; keep the local invoice because board swap is the product.
Daily: sun → house → battery → leftover export at ~Rs 11. Geyser and extra ACs stay off LOAD. Full maps: /manual-hybrid, /manual-lfp, /manual-plates, /manual-apps.
All user manuals · Commissioning · Plate care · LFP · Tubular · Hybrid · On-grid · Apps · Faults
Official manuals & datasheets
OEM PDFs live on the manufacturer site (and in the carton). We do not host pirated copies. Our operating manuals are original Zarkaar pages plus these manufacturer hubs. If the carton disagrees, the carton wins.
- Inverex product range (PK)
- Nitrox hybrid operating manual
- Mustang plate care
- Inverex LFP operating manual
- SmartESS / Solarman pairing
Plates
| Model | W | Cell | Rs/W | Street PKR | Warranty | Note | |
|---|---|---|---|---|---|---|---|
| VOLUME | Mustang TOPCon 585 W 16BB | 585 | N-type TOPCon | ~43 | ~25,155 | brand T&C | Local branded import. |
| VOLUME | Mustang 605–620 W steel frame DG | 610 | N-type TOPCon | ~43 | ~26,660 | brand T&C | Windproof steel-frame lots. |
| VOLUME | Jolywood 595–630 W dual-glass | 600 | N-type | ~44 | ~26,180 | brand T&C | Inverex-channel Jolywood. |
| FLAGSHIP | Mustang HJT 695–730 W | 710 | HJT | TBA | coming soon | lot | Listed coming soon on some Sep 2026 pages. |
Batteries
| Model | kWh | V | Chem | Street PKR | DoD | Cycles | Warranty | Note | |
|---|---|---|---|---|---|---|---|---|---|
| PREMIUM | INV-LV 5.12 kWh | 5.12 | 51.2 | LFP | 285–295k | 90% | 6000 | 5 yr local | Best with Nitrox CAN. |
| PREMIUM | Powerwall / Pro 51.2 V | 5.12 | 51.2 | LFP | 450–545k | 90% | 6000 | 5 yr local | Dear. Local replacement. |
| UPS | 12 V 100 Ah LFP | 1.28 | 12 | LFP | ~80k | 90% | 4000+ | 5 yr | Not a house bank. |
Inverters
| Model | kW | PV in | Type | Street PKR | Warranty | Note | |
|---|---|---|---|---|---|---|---|
| HOUSE | Nitrox 3–3.6 kW hybrid | 3.6 | 5.8 | Hybrid 1P 24 V | 125–215k | 5 yr | Small house / single AC day. |
| HOUSE | Yukon 3.5 kW hybrid | 3.5 | 5 | Hybrid 1P 24 V | ~165k | 5 yr | Older 24 V line. |
| HOUSE | Veyron II 4 kW | 4 | 6 | Hybrid 1P 24 V | ~198k | 5 yr | 24 V. Do not mix 48 V LFP. |
| HOUSE | Veyron II 6 kW | 6 | 8 | Hybrid 1P 48 V | ~235k | 5 yr | Volume 6 kW. |
| HOUSE | Nitrox 6 kW IP65 | 6 | 9 | Hybrid 1P 48 V | 210–275k | 5 yr | Zarkaar 6 kW default class. |
| HOUSE | Nitrox 8 kW | 8 | 12 | Hybrid 1P 48 V | ~295k | 5 yr | Fat PV headroom. |
| HOUSE | Nitrox 10 kW SP-5G hybrid | 10 | 16 | Hybrid 1P 48 V IP65 | 425–499k | 5 yr | Large house. |
| ON-GRID | Nitrox 10 kW 3P on-grid | 10 | 15 | On-grid 3P IP65 | ~280k | 5–10 yr | Dies in shed. |
| C&I | Nitrox 12 kW 3P hybrid | 12 | 18 | Hybrid 3P IP65 | 815–850k | 5 yr | Small mill / large kothi. |
| C&I | Nitrox 50–100 kW 3P on-grid | 75 | 110 | On-grid 3P | quote–1.3M+ | 10 yr some | Factory string. |
How to use each plate
Mustang TOPCon 585 W 16BB
Local branded import, not Hi-MO X10. Same torque and wash. Keep the Inverex invoice for the desk that actually swaps boards.
Mustang 605–620 W steel frame DG
Mount on 14 SWG GI (aluminium on salt air). Mid-clamp 12–15 N·m, end 20–25 N·m, OEM clamp zone only. One wattage per MPPT. Record cold-morning Voc vs flash. Wash at dawn. Register serials. Windproof steel-frame lots.
Jolywood 595–630 W dual-glass
Mount on 14 SWG GI (aluminium on salt air). Mid-clamp 12–15 N·m, end 20–25 N·m, OEM clamp zone only. One wattage per MPPT. Record cold-morning Voc vs flash. Wash at dawn. Register serials. Inverex-channel Jolywood.
Mustang HJT 695–730 W
Listed coming-soon on some Sep 2026 pages. Treat as C&I iron if it lands. Confirm flash before you pay HJT money.
How to use each battery
INV-LV 5.12 kWh
51.2 V LFP. Switch OFF, red +, black −, CAN-IN to inverter, protocol not USE, first charge to 100%, indoor under 45 °C. LCD charge current at or under the pack rating. Best with Nitrox CAN.
Powerwall / Pro 51.2 V
51.2 V LFP. Switch OFF, red +, black −, CAN-IN to inverter, protocol not USE, first charge to 100%, indoor under 45 °C. LCD charge current at or under the pack rating. Dear. Local replacement.
12 V 100 Ah LFP
12 V brick. Not a house bank unless the vendor sold a matched series kit with one BMS strategy. Not a house bank.
How to use each inverter
Nitrox 3–3.6 kW hybrid
24 V hybrid. Only 24/25.6 V batteries. LOAD vs GRID split. Battery + CAN first, then PV, then AC. Shed-test the fridge. Small house / single AC day.
Yukon 3.5 kW hybrid
24 V. Do not land a 51.2 V wall pack. Small house / single day AC.
Veyron II 4 kW
24 V hybrid. Only 24/25.6 V batteries. LOAD vs GRID split. Battery + CAN first, then PV, then AC. Shed-test the fridge. 24 V. Do not mix 48 V LFP.
Veyron II 6 kW
Hybrid. Read GRID vs LOAD silk-screen. Battery protocol on LCD (PYL/LIB/brand), not USE. Power-on: battery → program → PV → grid → LOAD. Shed test before handover. Volume 6 kW.
Nitrox 6 kW IP65
Zarkaar 6 kW house class. LOAD vs GRID. Battery+CAN first. SmartESS/Solarman. Shed-test fridge. 48 V pack only.
Nitrox 8 kW
Hybrid. Read GRID vs LOAD silk-screen. Battery protocol on LCD (PYL/LIB/brand), not USE. Power-on: battery → program → PV → grid → LOAD. Shed test before handover. Fat PV headroom.
Nitrox 10 kW SP-5G hybrid
Hybrid. Read GRID vs LOAD silk-screen. Battery protocol on LCD (PYL/LIB/brand), not USE. Power-on: battery → program → PV → grid → LOAD. Shed test before handover. Large house.
Nitrox 10 kW 3P on-grid
Dies in shed. Anti-islanding. Bidirectional meter before export. Wrong for a night-shed house.
Nitrox 12 kW 3P hybrid
Hybrid. Read GRID vs LOAD silk-screen. Battery protocol on LCD (PYL/LIB/brand), not USE. Power-on: battery → program → PV → grid → LOAD. Shed test before handover. Small mill / large kothi.
Nitrox 50–100 kW 3P on-grid
On-grid: dies when WAPDA dies (anti-islanding). Pair the brand app. Export only after a bidirectional meter. Not a shed house. Factory string.
Bands from Sep 2026 published lists. Confirm the lot flash / CAN protocol the week you book. Follow the carton user manual if it disagrees with a WhatsApp PDF.